Zhejiang Dixsen Electrical Co., Ltd.

DE-96V DC Square type Moving coil Analog DC Voltmeter

DE-96V DC Square type Moving  coil Analog DC  Voltmeter
Product Detailed

1.DE-96DC analogue voltmeters desined to measure
2.electrical meter extensive reange of electrical
3.meter factory

1.DE-96DC analogue voltmeters desined to measure
2.electrical meter extensive reange of electrical
3.meter factory

These meters measure the DC voltage with linear scale. The nominal mark is C.
Accuracy:Class 1.5
Specification:3V 5V 7.5V 10V 15V 20V 30V 50V 75V 100V 120V 150V 200V 250V 300V 400V 500V 600V
Measuring ranges over 450V with external resistor (rated current 5mA)
Case:Non-combustile ABS plastic material is used for making external case,and PPO plastic material is used for base; while Non-combustible PC plastic material is used for making T series'external case and base. Both of which will not suffer deformity under long-term use at 70°C and 120 C respectively.
Mounting: flush mounting with bracket.

 Moving Coil Instruments DC Volters

Model :DE-C96 DE-C72 DE-C48

Accuracy: Class 1.5

Specification: 3V 5V 7.5V 10V 15V 20V 30V 50V 75V 100V 120V 150V 300V 250V 300V 400V 450V 600V

Note: Over 6000Vshould be used with Ext.Resistor .

(Rated current 5mA)

Standards:

IEC51, IEC61010-1, VDE410, BS89, UL94, NE60051, DIN43780

Cases:

Temperature influence:

All cases at least dust and splash water-proof.
All cases are made of strengthened self-extingushing PPO
With a high hit-resistance and a maximum electric isolation

All instruments operate trouble-free at room temperature ranging from -25 to + 40.
The Max. Voltage to earth Voltmeter-The upper range voltage (full scale deflention)
Ammeter-The Voltage of the main power supply.
The meter used shall be keep cleaning. The user shall be made aware that, if the meter is used in a manner not specified by the manufacturer, the protection provided by the meter may be impaired.

Accuracy class:

AC, DC Voltmeters and Ammeters comply with the accuracy class 1.5.
The power meters comply with accuracy class 1.5.
The frequency meters comply with accuracy class1.0.
The maximum-demand meters comply with accuracy class 3.0.
The power factor meters and synchroscope meter comply with accuracy class 2.5.

Insulation test:

Mounting angle:

The insulation test is carried out at a voltage of 2KV, 50Hz 1 min and applies for instruments with the full scale deflection up to 650V. Other standards comply with IEC61010-1.

The instruments are calibrated for vertical mounting, unless other positions such as horizontal or inclined at any specified angle to the horizon. can be provided upon request (in this case, specify angle of inclination, please) The accuracy class refers to the specified mounting angle only.



Copyright Notice @ 2008-2022 B2BAGE Limited and/or its subsidiaries and licensors. All rights reserved.